Sensor shows Offline or a vessel has no readings

A device shows Offline or Low battery, a vessel says "No sensor installed", or readings stopped updating.

A device shows "Offline"

What you see: a red Offline pill in Settings → Hardware, with last seen "never" or some hours ago. You may also get a briefing: "Device hasn't reported in 4+ hours".

Why it happens: BarrelLogic hasn't received a reading from the device in more than 60 minutes. A device that has never sent a reading shows "never".

Sensors send their readings through your cellar hub, which needs power and a network connection to pass them on.

How to fix it:

  1. Check the hub. Make sure your cellar hub is powered and connected to your network.
  2. Check the distance. Make sure the sensor is within range of the hub.
  3. Check the battery. If the card showed Low battery before it went offline, the battery may be flat. See below.
  4. Wait for the next reading. As soon as one reading arrives, the device shows Online again.
  5. If it's still offline after that, email hardware@barrellogic.com with the device serial and its last-seen time.

The Restart button doesn't yet reach devices, so it won't bring an offline device back. Use the steps above instead.

"Low battery"

What you see: an amber Low battery pill and battery percentage, or a briefing "Device battery at N%".

Why it happens: the battery is below 15%.

How to fix it: replace the battery. Smart bungs use a CR2477 coin cell. Batteries are consumables with their own warranty terms; see the hardware warranty.

The vessel says "No sensor installed"

No sensor installed. Add a Smart Bung or Tri-Clamp in Settings · Hardware.

Why it happens: there are no sensor readings for this vessel from the last 7 days. That covers three situations:

  • no device is assigned to this vessel;
  • a device is assigned, but it's been offline for 7 days or more;
  • the device was assigned to this vessel recently, and its earlier readings belong to the vessel it was assigned to before.

How to fix it:

  1. In Settings → Hardware, find the device and check that it's assigned to this vessel. If not, click Assign and choose it.
  2. Check the device is Online. If it's offline, follow the steps above.
  3. Readings appear on the vessel as soon as the next one arrives.

"One reading so far — waiting for more."

The chart needs at least two readings to draw a line. Wait for the next one.

Readings look out of date

Check "Last 7 days · updated …" on the vessel's Live sensors panel, and the device's last-seen time in Settings → Hardware. If last seen is more than an hour ago, the device is offline; follow the steps at the top.

The device doesn't appear in Settings → Hardware at all

Devices only appear after they're activated. See Activating a sensor and assigning it to a vessel.

Still stuck?

Email us with your winery name, the page you were on, and the exact message you see. A screenshot helps.